The updated maximum likelihood technique determines the psychometric function parameters efficiently, reducing listener fatigue. In a study with 20 cochlear implant patients and 20 normal hearing participants, the method proved to be as accurate as the conventional STAIRCASE procedure. Moreover, it requires less effort from listeners, with a 1.3-minute average reduction in test duration when using a "credible interval" termination criterion.