The purpose of this study was to compare the clinical efficacy of a newly developed bilayered PCL membrane with a Cytoplast™ RTM collagen membrane for GBR with simultaneous implant placement. The percentage of reduced BBT at 6 months was 32.38%, 25.94%, and 23.96% in the test group and 34.42%, 14.75%, and 6.34% in the control group at the corresponding levels. Within the limits of this trial, both barrier membranes resulted in comparable outcomes for GBR with implant placement after 1 year in function. However, further research is necessary with a larger sample size.