.jpg?format=webp&width=780)
A study has shown positive outcomes for treating severe limb length discrepancies caused by Fibular Hemimelia (FH) and femoral shortening. The study involved 12 children, simultaneous femoral and tibial lengthening using the Ilizarov frame successfully corrected limb length discrepancies ranging from 7 to 14.5 cm in one session. This procedure resulted in a planned limb lengthening success rate of 83%, with no joint subluxation or neurovascular injuries. While there were minor issues with tibia regeneration in 16.6% of cases, the overall conclusion is that this approach offers a safer and more efficient solution for FH-related limb length discrepancies.