Myocardial scar is currently assessed non-invasively using cardiovascular magnetic resonance (CMR) late gadolinium enhancement (LGE) as an imaging gold-standard. However, a contrast-free approach would provide many advantages, including a faster and cheaper scan, without contrast-associated problems. VNE provided significantly better image quality than LGE on blinded analysis by 5 independent operators on 291 datasets (all p<0.001). VNE demonstrated high agreement with LGE-CMR for myocardial scar assessment in patients with prior myocardial infarction in visuospatial distribution and lesion quantification, with superior image quality. VNE is a potentially transformative AI-based technology, with promise to reduce scan times and costs, increase clinical throughput, and improve the accessibility of CMR in the very-near future.