14Jul 2024
Biomechanical Effects of Foraminoplasty During TESSYS: Finite Element Study

Biomechanical Effects of Foraminoplasty During TESSYS: Finite Element Study

The study assesses lumbar spine biomechanics post-foraminoplasty using large-channel endoscopy during TESSYS. It employs 3D finite element models to simulate surgical conditions and evaluates stress changes in facet joints and discs under various spinal movements. Findings highlight increased stress at specific joints and discs, cautioning against excessive resection during PTED procedures to mitigate biomechanical disruption.