Comparison of Fixation Methods for Short BSSO in Mandibular Advancement

Comparison of Fixation Methods for Short BSSO in Mandibular Advancement

The study compared three fixation methods for short BSSO. Polyurethane mandibular replicas underwent an 8-mm advancement and 6° counterclockwise rotation. Fixation with three bicortical screws or a hybrid system showed similar biomechanical performance to two miniplates with eight screws but with better cost efficiency. Findings suggest that simpler fixation methods may be preferable for stability and affordability in mandibular advancements.