09Feb 2025
ECMO Anticoagulation Tests Show High Discordance

ECMO Anticoagulation Tests Show High Discordance

In 85 ECMO patients, aPTT, anti-Xa activity, and R-time in TEG showed poor correlation and 46% discordance. Target range compliance was low (15–44%). Bleeding occurred in 67 patients, with anti-Xa activity linked to bleeding in VA-ECMO (OR 1.03, p=0.005). Lower aPTT was associated with reduced mortality (OR 0.98, p=0.024).

  • #cardiology

Like

Save

Share