To obtain additional information on the incremental differences between using a sensor‐augmented pump (SAP) without automated insulin delivery (AID), using it with predictive low‐glucose management (PLGM) or as a hybrid closed loop (HCL) in preschool and school children. The study conducted a monocentric, randomized, controlled, two‐phase crossover study in 38 children aged 2‐6 and 7‐14 years. In addition, results from 2 weeks of SAP, 8 weeks of PLGM and 8 weeks of HCL were compared using a paired t‐test or Wilcoxon signed‐rank test. Overall, we found a high rate of TIR target (>70%) achievement with HCL in preschool (88%) and school children (50%), with average times in Auto Mode of 93% and 87%, respectively. Preschool children profit from AID at least as much as those aged 7 years and older. Regulatory approval is also required for young children to ensure safe use and prescribing modalities.