Surgical reconstructions following Mohs micrographic surgery and standard surgical excisions are often closed with two layers of sutures: a deep subcuticular layer and a superficial cuticular layer. Some surgeons need to place many deep sutures to reduce tension on cuticular sutures, as they believe this may decrease incidence of track marks and dehiscence and lead to better cosmetic outcomes. There are no studies published on the effect of subcuticular suture spacing on wound cosmesis. The study found that 1‐cm suture spacing was not significantly associated with improved overall cosmetic outcome compared with 2‐cm suture spacing when evaluated by blinded observers or the patients themselves. The present study results support the use of either interval.