The study investigates the effect of mesiodistal distance on peri-implant bone preservation for multiple posterior implants. 102 patients were assessed using calibrated X-rays to measure inter-implant distances and bone resorption after prosthesis placement. The mesiodistal distance algorithm proved effective when there were significant differences in peri-implant bone levels between experimental and control groups. Smoking had no significant impact, highlighting the importance of inter-implant distance in predicting implant prognosis.