Two-way adjustable double-knots intrascleral fixation and single sclerotomy looping technique for intraocular lenses

The study introduced a novel two-way adjustable double-knots intrascleral fixation combined with a single sclerotomy looping technique for fixing intraocular lenses (IOL) without capsular support. A 30-gauge needle threaded with 8 − 0 polypropylene is used, with two overhand knots made and incarcerated into a scleral tunnel. The IOL is adjusted for optimal positioning. The 19 eyes showed increased uncorrected visual acuity (UCVA) from 1.28 ± 0.74 to 0.44 ± 0.51. IOLs are well-centered with a mean tilt of 3.5°±1.1°. Complications include transient IOP elevation (15.8%), hypotony (10.5%), and cystoid edema (5.3%), resolving within four weeks. The technique offers reliable IOL positioning and improved visual outcomes.